Tulsa, Oklahoma30+ days ago
Detect and repair leaks on racks or single-unit piping, solder with copper-to-brass and copper to steel, diagnose low air flow, install PVC drain pipe, replace evaporator/condenser motors, use temperature meters and sensors, receive, uncrate and properly hang blower coils, fabricate hangers, struts and supports, power wash air-cooled condensing units, repair Hussmann brand products, replace any component on a rack and perform walk-in case installation with some direction from a Master or Lead Technician. Demonstrate understanding of sub cool, superheat, refrigerant and oil properties, vacuums and microns, system evacuation and charging, system pump down, system defrost types, single phase compressor start components, recovery setup, torch setup, conventional refrigeration system layout, and parallel rack system layout.