W2 contract || Infrastructure Engineer

Noblesoft Technologies

  • Santa Clara, CA
  • 1 day ago

    Highlights

    Maintain a forward view of network room capacity available ports, fibre strand counts, PDU outlets, rack units, and power headroom and flag constraints ahead of demand. Define equipment placement within network rooms rack elevations and positions for network gear, security and BAS panels, service wall fields, pathway and containment routes.

    Numbers & Facts

    LocationSanta Clara, CA

    Description

    Role :- Site Infrastructure Engineer (RCDD)

    Location :- Santa Clara, CA(Onsite)

    Job type: Contract

    Note :- TIA-942 knowledge is mandatory and RCDD experience is Must.

    RCDD certification is not mandatory

    TIA 942 is the globally adopted ANSI/TIA standard defining minimum requirements for data center telecommunications infrastructure, covering site location, architecture, electrical and mechanical systems, fire safety, security, and redundancy, with the latest revision being ANSI/TIA 942 C published in May 2024.

    Construction and new builds low-voltage design, program delivery, vendor oversight

    ROLE SUMMARY

    Owns the IT infrastructure content of construction and lifecycle projects: new building deployments, network room build-outs, cabling projects, and refresh initiatives. Acts as Client technical authority to Facilities, architects, general contractors, and low-voltage subcontractors reviewing designs, producing specifications, controlling scope and materials, and holding contractors to the standard. This is a design and program-engineering role, not an installation role; execution is performed by contracted trades under this engineer's direction.

    KEY RESPONSIBILITIES

    Design and specification

    • Partner with Facilities, Network, AV, Security, and End User Support stakeholders to establish IT requirements for each project at the design stage.
    • Review architectural, electrical, and low-voltage drawings against Client standards; issue formal design comments and track resolution.
    • Produce construction documents, specifications, and installation standards for low-voltage cabling contractors.
    • Define equipment placement within network rooms rack elevations and positions for network gear, security and BAS panels, service wall fields, pathway and containment routes.
    • Specify pathway, grounding/bonding, fire-stopping, labelling, and testing requirements in line with TIA/BICSI standards and local code.

    Program and vendor delivery

    • Develop ROM and BOM for new builds and refreshes; drive procurement of long-lead materials against project milestones.
    • Oversee low-voltage contractors through installation, ensuring work is delivered to design specification and quality standard.
    • Issue Statements of Work and detailed working instructions to vendors; review and validate submittals, RFIs, and change orders.
    • Walk construction projects on a regular cadence and issue written site reports capturing Client feedback, defects, and corrective actions.
    • Manage punch-list closure, acceptance testing, and test-result review (fibre and copper certification) prior to sign-off.

    Closeout and handover

    • Compile and record close-out documentation as-built drawings, test results, warranty certificates, labelling schedules and hand over to the operations team and end users.
    • Ensure all newly delivered infrastructure is loaded into Netbox/Nautobot and CMDB before project closure.
    • Conduct formal handover walkthroughs so operations inherit a documented, supportable environment.
    • Capture lessons learned and feed improvements back into Client design standards and vendor specifications.

    Capacity and lifecycle engineering

    • Maintain a forward view of network room capacity available ports, fibre strand counts, PDU outlets, rack units, and power headroom and flag constraints ahead of demand.
    • Plan and scope lifecycle refresh initiatives for cable plant, racks, and power infrastructure.
    • Support regional power shutdown planning from an infrastructure design and risk perspective.

    REQUIRED SKILLS AND QUALIFICATIONS

    • Bachelor s degree in information technology, Engineering, Construction Management, or a related field, or equivalent experience.
    • 8+ years in low-voltage design, telecommunications consulting, IT construction project management, or structured cabling program delivery.
    • RCDD certification (or actively pursuing) this is the core credential for the design and specification scope.
    • Working command of TIA-568/569/606/607, BICSI TDMM practice, NEC low-voltage provisions, and applicable local building and fire code.
    • Ability to read and markup architectural, electrical, and telecom drawings; proficiency with AutoCAD, Revit, or Bluebeam for review and redline.
    • Demonstrated experience directing low-voltage subcontractors and general contractors, including SOW authoring, submittal review, and change-order control.
    • Deep understanding of network room infrastructure racks, containment, grounding, power distribution, cooling, and fibre/copper plant design.
    • Strong written communication; able to produce specifications, site reports, and closeout packages to a professional standard.
    • Comfortable operating with minimal direction in ambiguous, fast-moving construction environments.

    PREFERRED

    • 10+ years of related experience, including delivery of ground-up building or large campus fit-out projects.
    • Additional BICSI credentials (DCDC, OSP, RTPM) or PMP.
    • Experience delivering lab, cleanroom, or high-density compute environments.
    • Proficiency with DCIM/CMDB platforms, and with SQL, Python, or PowerBI/Tableau for capacity and program reporting.
    • Prior experience at a large-scale technology company or hyperscale operator.

    SERVICE MEASURES

    • Projects delivered to schedule and to design specification, with defects closed before handover.
    • Design reviews completed within agreed turnaround at each project gate.
    • BOM/ROM accuracy against final installed quantities.
    • Complete closeout documentation and CMDB records at every project completion.