Iconma logo

Facilities Engineer III

Iconma

  • Charlotte, NC
  • 28 days ago
  • $51.17–$56.17 Per Hour

Highlights

Partner with IT infrastructure modernization programs (e.g., dual-room resiliency to identify and eliminate physical constraints like insufficient UPS power, rack space limits, and lack of dual connections. Ensure racks are designed and positioned to support safe servicing, cable length constraints, and practical workflows as part of overall computer room layout best practices.

Numbers & Facts

LocationCharlotte, NC
IndustryManagement Consulting Services
Salary$51.17–$56.17 Per Hour
Company Size2,000 to 2,499 employees
Year Founded2000
Websitehttps://www.iconma.com/

Description

Our Client, a Business Maunufacturing and Supply company, is looking for a Facilities Engineer III for their Charlotte, NC location.
 
Responsibilities:
  • Power Requirements & Electrical Design (IT Load Planning)
  • Own IT power demand planning for manufacturing computer rooms: establish current and future rack power budgets, peak load assumptions, and growth buffers.
  • Produce/maintain documentation of power source paths, redundancy assumptions, and room feeding approach (e.g., dual feeds, generator transfer) consistent with site DR and readiness documentation practices
  • Coordinate with plant electrical/facilities teams on electrical capacity, panel space, circuits, breakers, and phased expansions.
  • UPS / Battery Backup Engineering & Runtime Targets
  • Define UPS strategy (central room UPS vs. rack UPS) and ensure capacity supports business uptime needs.
  • Manage UPS lifecycle: sizing, runtime targets, monitoring, inspection cadence, testing, vendor maintenance coordination, and replacement planning.
  • Support sites where UPS utilization is already a risk: e.g., communications on maintaining a “stop-gap” utilization threshold and planning larger capacity upgrades
  • Perform troubleshooting and improvement planning for UPS/battery systems aligned with critical facilities operating practices
  • Rack Elevations, Physical Layout, and Capacity Modeling
  • Create and maintain rack elevations and “as-built” room layouts to support safe installation, maintenance access, and growth.
  • Ensure racks are designed and positioned to support safe servicing, cable length constraints, and practical workflows as part of overall computer room layout best practices.
  • Maintain CAD-style documentation and keep drawings current as the environment evolves
  • Site Readiness, Modernization Support, and Constraint Removal
  • Partner with IT infrastructure modernization programs (e.g., dual-room resiliency to identify and eliminate physical constraints like insufficient UPS power, rack space limits, and lack of dual connections.
  • Drive remediation plans in coordination with facilities teams while minimizing production impact
  • Operational Excellence: Risk, Change, and Incident Support
  • Serve as the facilities escalation point for computer room power events, and participate in root cause analysis and remediation planning for electrical failures.
  • Establish/maintain SOPs/MOPs for planned power work, UPS maintenance, rack adds/moves/changes, and room upgrades.
  • Provide QA/QC oversight for contractor work impacting computer rooms and critical electrical paths
  • Stakeholder, Vendor, and Contractor Management
  • Manage vendor relationships for UPS, battery, and monitoring systems; coordinate quotes, SOWs, and delivery timelines for upgrades (including cases where site power capacity expansion is required).
  • Collaborate with plant maintenance on generator/transfer readiness and testing practices where applicable.
  • Provide overall management of the Struxure ware DCIM Platform
 
Requirements:
  • Bachelor's degree (B.A.) or equivalent from four-year college in computer science or related field or equivalent experience
  • 5+ years of experience in critical facilities / electrical infrastructure / data center or computer room environments, ideally supporting industrial or manufacturing facilities
  • Hands-on expertise with UPS systems, battery technologies, and electrical distribution, including troubleshooting and operational safety protocols.
  • Demonstrated capability producing and maintaining rack elevations/layouts and validating power/thermal/weight constraints.
  • Experience with generators, ATS/STS units, and mission-critical electrical systems operations.
  • Familiarity with industry data center tiering concepts and reliability-oriented design thinking
 
Why Should You Apply?

Benefits

401K, Employee Referral Program, Life Insurance

About Company

ICONMA is a global information consulting management firm providing Professional Staffing Services and Project-Based Solutions for organizations in a broad range of industries.

  • Corporate Headquarters in Troy, Michigan; 20+ locations worldwide.
  • Certified Woman-Owned Business Enterprise (WBE); certified by Women’s Business Enterprise National Council, National Women Business Owners Corporation (NWBOC); and California Public Utilities Commission (CPUC).
  • Founded in 2000
  • 2000+ Employees

The company was founded on the principle that success is derived from delivering high quality service and resources in the most responsive, flexible, and innovative way. ICONMA invests in people and resources with a single goal: To provide our customers with the highest quality service in the most responsive manner. Through its network of offices, ICONMA provides the resources to help clients maintain their competitive advantage.

Similar Jobs