Site Infrastructure Engineer (RCDD)

Vdart Inc

  • California, CA
  • 6 days ago

    Highlights

    Maintain a forward view of network room capacity - available ports, fibre strand counts, PDU outlets, rack units, and power headroom - and flag constraints ahead of demand. Define equipment placement within network rooms - rack elevations and positions for network gear, security and BAS panels, service wall fields, pathway and containment routes.

    Numbers & Facts

    LocationCalifornia, CA

    Description

    Role :- Site Infrastructure Engineer (RCDD)

    Location :- Santa Clara, CA(Onsite)

    Contract

    Note :- TIA-942 knowledge is mandatory and RCDD experience is Must.

    RCDD certification is not mandatory

    TIA‑942 is the globally adopted ANSI/TIA standard defining minimum requirements for data center telecommunications infrastructure, covering site location, architecture, electrical and mechanical systems, fire safety, security, and redundancy, with the latest revision being ANSI/TIA‑942‑C published in May 2024.

    Construction and new builds - low-voltage design, program delivery, vendor oversight

    ROLE SUMMARY

    Owns the IT infrastructure content of construction and lifecycle projects: new building deployments, network room build-outs, cabling projects, and refresh initiatives. Acts as Client technical authority to Facilities, architects, general contractors, and low-voltage subcontractors - reviewing designs, producing specifications, controlling scope and materials, and holding contractors to the standard. This is a design and program-engineering role, not an installation role; execution is performed by contracted trades under this engineer''s direction.

    KEY RESPONSIBILITIES

    Design and specification

    • Partner with Facilities, Network, AV, Security, and End User Support stakeholders to establish IT requirements for each project at the design stage.
    • Review architectural, electrical, and low-voltage drawings against Client standards; issue formal design comments and track resolution.
    • Produce construction documents, specifications, and installation standards for low-voltage cabling contractors.
    • Define equipment placement within network rooms - rack elevations and positions for network gear, security and BAS panels, service wall fields, pathway and containment routes.
    • Specify pathway, grounding/bonding, fire-stopping, labelling, and testing requirements in line with TIA/BICSI standards and local code.

    Program and vendor delivery

    • Develop ROM and BOM for new builds and refreshes; drive procurement of long-lead materials against project milestones.
    • Oversee low-voltage contractors through installation, ensuring work is delivered to design specification and quality standard.
    • Issue Statements of Work and detailed working instructions to vendors; review and validate submittals, RFIs, and change orders.
    • Walk construction projects on a regular cadence and issue written site reports capturing Client feedback, defects, and corrective actions.
    • Manage punch-list closure, acceptance testing, and test-result review (fibre and copper certification) prior to sign-off.

    Closeout and handover

    • Compile and record close-out documentation - as-built drawings, test results, warranty certificates, labelling schedules - and hand over to the operations team and end users.
    • Ensure all newly delivered infrastructure is loaded into Netbox/Nautobot and CMDB before project closure.
    • Conduct formal handover walkthroughs so operations inherit a documented, supportable environment.
    • Capture lessons learned and feed improvements back into Client design standards and vendor specifications.

    Capacity and lifecycle engineering

    • Maintain a forward view of network room capacity - available ports, fibre strand counts, PDU outlets, rack units, and power headroom - and flag constraints ahead of demand.
    • Plan and scope lifecycle refresh initiatives for cable plant, racks, and power infrastructure.
    • Support regional power shutdown planning from an infrastructure design and risk perspective.

    REQUIRED SKILLS AND QUALIFICATIONS

    • Bachelor's degree in information technology, Engineering, Construction Management, or a related field, or equivalent experience.
    • 8+ years in low-voltage design, telecommunications consulting, IT construction project management, or structured cabling program delivery.
    • RCDD certification (or actively pursuing) - this is the core credential for the design and specification scope.
    • Working command of TIA-568/569/606/607, BICSI TDMM practice, NEC low-voltage provisions, and applicable local building and fire code.
    • Ability to read and markup architectural, electrical, and telecom drawings; proficiency with AutoCAD, Revit, or Bluebeam for review and redline.
    • Demonstrated experience directing low-voltage subcontractors and general contractors, including SOW authoring, submittal review, and change-order control.
    • Deep understanding of network room infrastructure - racks, containment, grounding, power distribution, cooling, and fibre/copper plant design.
    • Strong written communication; able to produce specifications, site reports, and closeout packages to a professional standard.
    • Comfortable operating with minimal direction in ambiguous, fast-moving construction environments.

    PREFERRED

    • 10+ years of related experience, including delivery of ground-up building or large campus fit-out projects.
    • Additional BICSI credentials (DCDC, OSP, RTPM) or PMP.
    • Experience delivering lab, cleanroom, or high-density compute environments.
    • Proficiency with DCIM/CMDB platforms, and with SQL, Python, or PowerBI/Tableau for capacity and program reporting.
    • Prior experience at a large-scale technology company or hyperscale operator.

    SERVICE MEASURES

    • Projects delivered to schedule and to design specification, with defects closed before handover.
    • Design reviews completed within agreed turnaround at each project gate.
    • BOM/ROM accuracy against final installed quantities.
    • Complete closeout documentation and CMDB records at every project completion.

    Similar Jobs