CR: Fuji DynamIx – HR2 PHYSICAL JOB DEMANDS: ACTION Weight N/A Occasional 1 - 33% Frequent 34 - 66% Constant 67 - 100% Max Avg Pushing - Assisted 50 Pulling - Assisted 50 X Floor to Knuckle Lift so X Knuckle to Shoulder Lift 50 x Shoulder to Overhead Lift Carrying Sitting Standing Walking Climbing Stairs Sustained Bending Overhead Reaching x Crawling Squatting (Repeated) Kneeling x Stooping (Repeated Bending) X Crouching X Climbing Ladders Balancing Handling X Fingering Feeling Talking X Hearing x Tasting Smelling Near Acuity Far Acuity Depth Perception X Color Perception X Peripheral Vision Repetitive motion Trip hazards High ambient temperatures & Head hazards Personal Protective Equipment Required• PPE Additional Information Head Protection: No Hearing Protection: Yes Glasses: Yes Side Shields: Yes Permanent Attachment (Yes or No): Yes Face Shield: No Goggles: No Other Eye Protection: No Other Face Protection: No Chest Guards: No Sleeve/Arm Guards: No Gloves: Yes Depending upon task being performed. Other Position Demands or Requirements: Must be able to use the following machines, tools, equipment and/or work aids: RT: X-Ray Machines: Comet 160KV/22 XRG controller, Comet 320/26 Ivario controller and Comet 320/11 MP1 controller; fully automatic Waygate NDT-U film processor; Penetrex High Intensity Dual Window, FV-2014 viewer, KOWOLUX X5 viewer; light meter; magnifying glasses 3X to 10X; penetrameters; lead screens; light tight vinyl cassettes; DT-300 densitometer; Fuji- Class I, II, and Class III safety films; DR: DDA Hardware: PiXS DR Custom Dual Robotic.
Numbers & Facts
Location
Denison, Texas
Website
https://denisonindustries.com/careers/
Description
Denison Industries
JOB DESCRIPTION
Job Title: FILM AND NON-FILM RADIOGRAPHY TECHNICIAN LEVEL ll
Employment Status:
Full-Time
FLSA Status:
Non-Exempt
Department:
Quality —Non-DestructiveTesting
Position Reports To:
Director of Quality/NDT Supervisor
Summary Description:
Radiograph utilizing film and non-film processes and accept/reject aluminum castings. Direct or carry out tests in the method certified, to the prescribed process specification. Set-up and calibrate equipment, where applicable, and interpret and evaluate results with reference to applicable codes, standards and specifications. Apply familiarity with the scope and limitations for the method and apply detailed techniques to the parts within the limit of his/her qualifications. Organize and report test results and prepare written instructions. Use familiarity with the type and location of expected defects for the fabrication process used to make the parts and exercise assigned responsibility for on-the-job training and guidance of trainees and Level I personnel.
Essential Functions:
Align object on stand between source of x-rays and film
Mask peripheral areas with lead shields
Select type of film, and determine exposure distance and time
Verify radiation intensities
Adjust controls of x-ray equipment on console to take radiograph
Remove and develop film
Monitor working area to protect personnel
Mark defects appearing on film and assist in analyzing findings
Set up and shoot castings using DDA Radiography equipment and techniques
Perform required checks and calibrations to customer and industry specifications
Investigate suspected discontinuities in castings using correct procedures and make accept/reject decisions based on those procedures
Perform any and all other job related tasks as assigned
Skills or Experience Required:
Must have High School diploma or GED; Radiation Safety Card for the state of Texas (preferred); Level II Film Radiography (RT) certification; Level II Non-film Radiography (CR or DR) certification (preferred) must have 40 hours of formal training/1200 hours experience as a Level I on Radiographic Experience with Aerospace castings (preferred).
Other Position Demands or Requirements:
Must be able to use the following machines, tools, equipment and/or work aids:
RT: X-Ray Machines: Comet 160KV/22 XRG controller, Comet 320/26 Ivario controller and Comet 320/11 MP1 controller; fully automatic Waygate NDT-U film processor; Penetrex High Intensity Dual Window, FV-2014 viewer, KOWOLUX X5 viewer; light meter; magnifying glasses 3X to 10X; penetrameters; lead screens; light tight vinyl cassettes; DT-300 densitometer; Fuji- Class I, II, and Class III safety films;
Pants may not be shorter than the Shoe/Boot being worn.
Shirt:
Yes
May be sleeveless with Supervisor permission.
Clothing Type:
Yes
Cotton or Wool
Fall Arrest:
No
Respirator:
No
Disclaimer: This job description is not intended, nor should it be construed to be an exhaustive list of all
responsibilities, duties, skills, or working conditions associated with a particular job. It is intended only to be a general description of the essential functions common to positions of this type.